Maximum Flush Volume: 1.6 gpf and the Energy Policy Act of 1992

Code Stories · PressureTest

The rule in Massachusetts today

Verbatim: 10.10(2)(f) "Toilets shall use a maximum of 1.6 gallons (6.0 liters) per flush." 10.10(3)(c) "Urinals shall use a maximum of one gallon (3.8 liters) per flush." 10.10(4)(c)3 "Shower heads shall use a maximum of 2.0 gallons per minute (G.P.M.)." 10.10(10)(a)2 "The maximum flow rate for faucets shall not exceed 0.5 gallons per minute (G.P.M.)".

New water closets: maximum 1.6 gallons (6.0 liters) per flush (248 CMR 10.10(2)(f))

Why it exists

Toilets are one of the largest indoor water uses, and every gallon flushed also has to be pumped, treated and carried by the sewer. Cutting flush volume saves both supply and wastewater capacity at the same time.

Why it exists (cont.)

The federal law set a uniform national ceiling so manufacturers had to redesign bowls and trapways around less water. Swapping a smaller tank onto an old bowl was the shortcut that gave early low-flow toilets a bad name.

1988

Massachusetts adopts a phased-in 1.6-gallon requirement.

Source: https://www.csmonitor.com/1990/0620/dplumb.html

1970s-1990

Why early low-flow toilets were bad: manufacturers put smaller tanks on bowls designed for more water.

Source: https://www.csmonitor.com/1990/0620/dplumb.html

1992

Energy Policy Act of 1992 enacted (Public Law 102-486).

Source: https://www.govinfo.gov/content/pkg/STATUTE-106/pdf/STATUTE-106-Pg2776.pdf

1992

EPAct's water closet standard as codified at 42 U.S.C. 6295(k).

Source: https://www.law.cornell.edu/uscode/text/42/6295

1994-1997

Transitional exceptions: 'Commercial Use Only' 2-piece gravity toilets at 3.5 gpf until 1997; flushometer-valve toilets 1.6 gpf after Jan 1, 1997; urinals 1.0 gpf.

Source: https://www.law.cornell.edu/uscode/text/42/6295

2012

Alliance for Water Efficiency on the size of the cut.

Source: https://allianceforwaterefficiency.org/20-years-energy-policy-act-18-trillion-gallons-saved-through-more-efficient-toilets/

Make it stick

Mnemonic: 'Mass. went first in '88; the feds followed in '92.' And a true image for why the first low-flows clogged: a Volkswagen engine in an Oldsmobile (CSM, 1990).

Myth

The federal law made people rip out old toilets.

Reality

The standard applies to products manufactured after the effective dates. It is not a retrofit mandate.

Myth

1.6 gpf was a federal idea.

Reality

Massachusetts passed a 1988 law phasing in the 1.6-gallon standard (CSM 1990), four years before EPAct 1992 made it national.

Myth

Low-flow toilets can't work.

Reality

Early failures came from putting small tanks on old bowl designs (CSM). Redesigned bowls and trapways solved that.

Check 1

The maximum flush volume for a new water closet is:

  1. 1.0 gallon
  2. 3.5 gallons
  3. 5.0 gallons
  4. 1.6 gallons

248 CMR 10.10(2)(f) caps new water closets at a maximum of 1.6 gallons (6.0 liters) per flush. Lower-flow models are allowed, but 1.6 gpf is the code maximum the exam tests.

Now practice it

pressuretest.me/learn/max-flush-volume-1-6-gpf/